1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859 |
- FreeTDM can both notify and set signaling status changes in the different protocols thru a unified interface. More
- specific details on the C data types and function prototypes are found in freetdm.h
- The API provides the following functions and data types to do it:
- The signaling status in any channel/span is represented thru ftdm_signaling_status_t
- /* The signaling link is down (no d-chans up in the span/group, MFC-R2 bit pattern unidentified) */
- FTDM_SIG_STATE_DOWN,
- /* The signaling link is suspended (MFC-R2 bit pattern blocked, PRI maintenance, ss7 blocked?) */
- FTDM_SIG_STATE_SUSPENDED,
- /* The signaling link is ready and calls can be placed (ie: d-chan up, MFC-R2 both rx and tx in IDLE) */
- FTDM_SIG_STATE_UP,
- /* Invalid status */
- FTDM_SIG_STATE_INVALID
- Changes in the signaling status are notified to the user using the standard callback notification function provided
- during configuration using the sigevent type FTDM_SIGEVENT_SIGSTATUS_CHANGED which is sent when the line status changes.
- On startup the signalling status default is FTDM_SIG_STATE_DOWN, and no notification is provided until the state change,
- so applications must assume the status is down unless told otherwise.
- When ftdm_span_start is called, the signaling stack takes care of attempting to bring the status to UP
- but it will ultimately depend on the other side too.
- == Setting the signaling status ==
- Users can set the signaling status on a given channel/span thru FreeTDM the following API functions:
- ftdm_channel_set_sig_status
- ftdm_span_set_sig_status
- If the user calls ftdm_channel_set_sig_status(chan, FTDM_SIG_STATE_SUSPENDED), the signaling stack will try to set
- the status of the line to the one requested, if successful, it will result in a SIGEVENT_SIGSTATUS_CHANGED notification
- being sent with status FTDM_SIG_STATE_SUSPENDED.
- ** MFC-R2 Signaling Notes **
- For MFC-R2, calling ftdm_span_start() results in setting the tx CAS bits to IDLE. However, if the rx bits are in BLOCKED state
- the signaling status will be reported as SUSPENDED.
- If the user calls ftdm_channel_set_sig_status(chan, SUSPENDED), the tx CAS bits will be set to BLOCKED and, if, the current rx bits
- are IDLE then a SIGEVENT_SIGSTATUS_CHANGED with state SUSPENDED will be sent. If the rx bits are already in blocked then no further
- SIGEVENT_SIGSTATUS_CHANGED notification is needed (because it was already sent when the rx bits were initially detected as BLOCKED).
- If the user calls ftdm_channel_set_sig_status(chan, UP), the tx CAS bits will be set to IDLE and, if, the current rx bits
- are IDLE, then SIGEVENT_SIGSTATUS_CHANGED with state UP will be sent. If the rx bits are BLOCKED, then no notification is
- sent at all until the rx bits change.
- Bottom line is, for MFC-R2, SIGEVENT_SIGSTATUS_CHANGED UP is only sent to the user when both the rx and tx bits are in IDLE, and
- SIGEVENT_SIGSTATUS_CHANGED SUSPENDED is only sent to the user when any of the rx or tx bits are in BLOCKED.
- == Getting the signaling status ==
- Users can get the signaling status on a given channel/span thru FreeTDM the following API functions:
- ftdm_channel_get_sig_status
- ftdm_span_get_sig_status